Research project · SDU and enervisual
HYG: hygrothermal performance of exterior walls
Temperature and humidity measured inside the exterior walls of homes in Denmark, Greenland and Canada, from August 2022 to July 2026. A research project of the University of Southern Denmark (SDU), supported by Realdania. Sensors and data platform by enervisual.
- Houses with data
- 44
- Sensors
- 265
- Readings
- 7.2 million
- Measuring period
- Aug 2022 – Jul 2026
Welcome to the HYG research project
How do exterior walls behave in real homes, year after year? Wireless sensors placed on the interior and exterior side of the north and south walls, plus one indoors and one outdoors, record temperature and relative humidity around the clock. The data shows how moisture moves through different wall constructions in different climates, and where the risk of mould growth is.
Use the tabs above to explore the data: follow one house, compare houses with the same wall type or house type, check the summary statistics, download the readings, or plot a sensor against the mould-growth limits in the isopleth.
Charts start with the last three weeks of measurements. Every chart has a period selector that reaches back to the first readings in August 2022. Times are UTC. Last reading shown: 2026-07-31 23:59 UTC.
Locations of the houses
Each dot is a postcode area, not a house. Houses are only identified by their project number.
Data distribution
How the readings spread per country: temperature in °C and relative humidity in %.
About the project
HYG (Hygrotermisk ydeevne af ydervægge, hygrothermal performance of exterior walls) is run by the University of Southern Denmark, SDU Civil and Architectural Engineering, and is supported by the philanthropic association Realdania. Read the project description at SDU.
Sensors and data
The battery-powered wireless sensors, the data collection and this page are provided by enervisual. Read how SDU uses enervisual sensors, or see our environmental sensors.
Each point is the mean of one sensor over an hour (periods up to 45 days) or a day (longer periods). Colour shows the sensor position; hover a point to see the house.
Each point is the mean of one sensor over an hour (periods up to 45 days) or a day (longer periods). Colour shows the sensor position; hover a point to see the house.
| House | Postcode area | Sensor | Readings | Temp. mean °C | min | max | RH mean % | sd | min | max | Last reading (UTC) |
|---|
Download the readings
The file holds every reading in the chosen period: time (UTC), house number, postcode area, sensor position, temperature in °C and relative humidity in %. Failed readings, reported by the sensor as 6553.5 %, are left out.
One house can be downloaded for the whole project period. For all houses at once, choose a period of up to 92 days.
Please cite the HYG project at the University of Southern Denmark when you use the data.